Part Number Hot Search : 
H5610 AT1604CI STBP022 D4613H 30C20 70246 MAX41 4N60F
Product Description
Full Text Search
 

To Download MFC15-24S Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  ver : a_2 update : 2016.02.22 ac -dc medical power module mfc15 series 15 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -1- electrical specifications all specifications valid at normal in put voltage, full load and +25c after warm-up time unless otherwise stated. model no. mfc15-5s mfc15-9s mfc15-12s mfc15-15s MFC15-24S max output wattage (w) 15w voltage (note 1) 90-264 vac or 120-370 vdc, ? n ? to dc ? + ? ; ?l ? to dc ? - ? frequency (hz) 47-440 hz current (full load) 385 ma max. (115 vac) / 250 ma max. (230 vac) inrush current (<2ms,cold start) 20 a max. (115 vac) / 40 a max. (230 vac) leakage current < 0.1ma / 264 vac (touch current) input external fuse (recommend) 3.15 a slow blow type voltage (v.dc.) 5v 9v 12v 15v 24v voltage accuracy 2% current (ma) max 3000 1666 1250 1000 625 maximum capacitive load (at 230 vac) 7000uf 5000uf 1500uf 1000uf 470uf line regulation (ll-hl) (typ.) 0.5% load regulation (5-100%) (typ.) 1%. ripple (full load) (note 2) 75mv max (vp-p) 1% of vout noise (full load) (note 2) 120mv max (vp-p) 1% of vout efficiency (at 230 vac) 79% 80% 84% 84% 85% output hold-up time(typ) 15 ms (115vac) / 56ms (230vac) over power protection hicc up technique, auto-recovery over voltage protection zener diode clamp protection short circuit protection hiccup mode, indefinite (automatic recovery) isolation input-output (v.ac) 4000v operating temperature -40c?+80c (with derating) storage temperature -40c?+90c max case operating temperature under 115 vac 83c , others 90c temperature coefficient 0.05%/c altitude during operation 5000m humidity up to 95% rh mtbf >350,000 h @ 25c (mil-hdbk-217f) environment atmospheric pressure 70 kpa to 106 kpa dimension (l x w x h) 2.07 x 1.08 x 0.93 inches ( 52.5 x 27.5 x 23.5 mm ) tolerance ? 0.5 mm case material plastic resin (flammability to ul 94v-0) weight 59 g physical cooling method free air convection key features ? switching power module for pcb mountable ? fully encapsulated plastic case ? universal input range 90-264vac ? regulated output and low ripple and noise ? <0.1w no load input power ? isolation class ii ? small size ? ce, cb, ul, cul approvals ? 3-year product warranty
ver : a_2 update : 2016.02.22 ac -dc medical power module mfc15 series 15 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -2- electrical specifications all specifications valid at normal in put voltage, full load and +25c after warm-up time unless otherwise stated. model no. mfc15-5s mfc15-9s mfc15-12s mfc15-15s MFC15-24S safety approval cul / ul standard: ul 60950-1, can/csa c22.2 no. 60950-1-07 ansi/aami es60601-1 (2005 + c1:09 + a2:10), can/csa-c22.2 no. 60601-1 (2008), 2 x mopp cb standard: iec 60950-1:2005 (2nd edition) + am 1:2009 + am 2:2013 iec 60601-1:2005 (3rd edition) + corr. 1 (2006) + corr. 2 (2007) + am1 (2012) or iec 60601-1 (2012 reprint), 2 x mopp conducted and radiated emi en55011 class b esd en61000-4-2 air 8kv , contact 4kv radiated immunity en61000-4-3 10v/m fast transient en61000-4-4 2kv surge en61000-4-5 1kv conducted immunity en61000-4-6 10vrms pfmf en61000-4-8 30a/m dips en61000-4-11 30% 10ms emc interruption en61000-4-11 >95% 5000ms note 1. this product is not designed for use in critical life suppor t systems, equipment used in hazardous environment, nuclear control systems or other such applications wh ich necessitate specific safety and regulatory standards other the ones listed in this datasheet. 2. ripple & noise are measured at 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor. 3. safety approvals cover frequency 47-63 hz. 4. that ?natural convection? is about 20lfm but is not equal to still air (0 lfm). 5. it's recommended to add varistor 14s471k at l / n input side in parallel. 6. please refer to our pdf file "ac-dc applic ation" on our website: www.archcorp.com.tw mechanical dimension pin# single 1 ac in (l) 2 ac in (n) 3 +dc out 4 -dc out maximum torque . ( . . )
ver : a_2 update : 2016.02.22 ac -dc medical power module mfc15 series 15 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -3- derating block diagram


▲Up To Search▲   

 
Price & Availability of MFC15-24S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X